Dirt builds up where you can't see it

The outdoor coil gets coated with dust and grass clippings, and the indoor coil collects what the filter didn't catch. A dirty coil can't shed heat the way it should, so the system runs longer to do the same job and the compressor takes the strain.

Small failures don't stay small

A weak capacitor or a slow refrigerant leak gets caught during a check of the electrical connections and the charge. Left alone, the compressor keeps working against that weakness until it's the part that fails, and a compressor is not something a tech can patch on the spot.

5 months
May through September, your air conditioner is on duty
90°F
the average summer afternoon it cools against
29 hail events
in ten years, and hail bends the fins on outdoor coils
55 wind events
in ten years, and wind drives debris into outdoor units
Isometric cutaway illustration of a house with a dark shingled roof, showing interior ductwork connected to an indoor air handler and an outdoor condenser unit beside the building.
Your air conditioner works hardest from June through September.

NOAA nClimDiv, 1991–2020 normals

Cooling in Logan County starts in May and runs through September.

April is when a tech can still get to the coil and the capacitor before the system is running flat out.

Built by 1979 or not, an AC here is young next to the work it's doing

Half the homes here were built by 1979
Cooling runs May through September
Summer afternoons average 90°F

May through September is five months of afternoons near 90 degrees, and a weak capacitor or a coil that's starting to go usually makes it through spring without showing anything. It's the run of hot days back to back that finds the weak spot. Getting the system checked before that stretch starts means a tech can still test the capacitor under load and get at the coil before either one is carrying the full load of summer. Wait until the heat's already here and you're finding out the same thing the hard way, on a day when the house needs the cooling most.

Get ahead of five months of Logan County heat

Five months of summer here, with afternoons in the 90s from June through August. That is a long stretch for a capacitor or a coil to carry the load without a check. Get it looked at before the heat sets in for the season.

Find a contractor
A man seen from behind, wearing a dark long-sleeved shirt and brown pants, carries a canvas tool bag as he steps up wooden porch stairs toward a green front door, with a potted plant beside the entry.
A gray residential air conditioner condenser unit mounted on a concrete pad in an open grass field.

Hours on the clock wear the coil, the filter and the drain alike

Every hour this system runs, air moves across the filter and over the indoor coil before it ever reaches the room. A clean filter lets that air pass freely. A clogged one chokes it down, and the coil behind it gets less air than it needs to give up heat the way it's built to. Run it long enough in that state and the coil can frost over even on a hot day, which shuts cooling down until it thaws. The condensate drain is doing its own quiet job through all of this, carrying away the water the indoor coil pulls out of the air. That line is narrow, and it sits wet the whole time the system runs, so algae and sludge build up along the inside of it. A blocked drain backs water up into the pan beneath the coil, and from there it finds the ceiling or the floor below. None of these parts fail on their own schedule. They wear on however many hours the system logs, season after season, for as long as it's asked to run.

The reading tells the story

A tech checks the refrigerant charge against what the system is supposed to carry, and checks the temperature of the air coming off the indoor coil against the air going into it. Both numbers can look fine to a homeowner standing in the room. A charge that's a little low still blows cold air, just not as cold as it should, and most people have no way to know the difference without the gauges.

A motor shows wear before it shows failure

The blower motor and the outdoor fan motor both run on bearings, and bearings wear down slowly long before a motor actually quits. A tech can hear a bearing starting to go, or feel a motor running hotter than it should, or catch it pulling more current than it should. Any of those is a motor working toward a breakdown that would otherwise show up as the system simply not turning on.

Aerial view of a gray outdoor air conditioning condenser unit mounted on a concrete pad next to a house with vinyl siding.

Book your AC tune-up in April, before homes here start needing cooling in May.

  1. Jan
  2. Feb
  3. Mar
  4. Apr
  5. May
  6. Jun
  7. Jul
  8. Aug
  9. Sep
  10. Oct
  11. Nov
  12. Dec

A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.

A tune-up starts outside at the condenser. The coil gets washed clean, the fan blades get checked, and the refrigerant charge gets measured against what the system is built to hold. Inside, the evaporator coil gets looked over and the drain line gets checked for the algae that builds up in a narrow, wet space. Electrical connections get tightened, since a loose connection runs hotter and wears faster than a tight one. The capacitor gets tested under load, not just looked at, because a capacitor can look fine and still be failing. Every moving part gets lubricated where it's supposed to be lubricated. None of this is guesswork. It's the same checklist run the same way, because the parts that fail in this kind of system fail in the same handful of places every time.